Features ProCam® Align Inline
Alignment degrees of freedom (DoF) up to 6
6 DoF linear alignment resolution < 0.1 µm
Final sample linear alignment accuracy < 2 µm
6 DoF tilt alignment resolution < 0.1 arcsec
Final sample tilt alignment accuracy < 2 arcmin
Sample Effective Focal Length 1 to 12 mm (others on request)
Sample diameter 2 to 30 mm (others on request)
Field of View test chart
Field of View collimators
up to 70 °
up to 170 °
Max. UPH (Units Per Hour) 240* (single head, parallelization possible)
Camera interface MIPI, SPI, various analog, USB, FireWire, CamLink, GigE, custom (CAN, etc.)
Dispense technologies several options
LED UV cure several options
Post-curing optional (UV/thermal)

* depending on camera module frame rate, length of curing process and number of different parameters to be measured